Key takeaways
- Resistive: Heaters, heat tape and similar loads. The HB113’s resistive rating is 20 amps at 125 volts.
- Motor: Pumps, compressors and air conditioners have startup surges. The HB113 lists a one-horsepower motor rating. Check your appliance’s rating plate.
- Tungsten: Incandescent lighting has a much lower limit than resistive heating; look for the tungsten figure on the timer’s label.
- LED and electronic loads: Some timers have minimum or special load ratings for LEDs and electronics. Read the maker’s rating.
- Plug configuration: The HB113 has a 5-20 plug, which needs a matching 20-amp receptacle. A standard 15-amp receptacle does not accept it. Do not modify plugs or receptacles to force a fit.
For a 20-amp outlet timer, the clearest plug-in choice is Intermatic’s HB113 heavy-duty appliance timer, rated by the maker at 20 amps resistive and 125 volts with a 5-20 plug and receptacle, and the main hardwired choices are Intermatic’s in-wall KM2ST-1G mechanical timer or EI600 series electronic timers, or the Legrand Pass and Seymour PLT26351BK heavy-duty plug-load timer receptacle. Pick the plug-in HB113 if you need to time a single heavy appliance, such as a window air conditioner, without touching the wiring, and pick a hardwired timer if you want a permanent installation on a 20-amp circuit. Hardwired timers replace a switch or receptacle, so follow the manual and local code and use a licensed electrician where required.
Why a 20-amp rating matters
Most ordinary plug-in timers are rated for 15 amps. A 20-amp circuit uses a different outlet pattern, with a T-shaped slot for the 20-amp plug on the neutral side, and appliances such as window air conditioners, large pumps or heavy-duty heaters can draw close to or above 15 amps. A timer’s rating depends on the load type. A resistive load, such as a heater, is the easiest. A motor load, such as a pump or air conditioner, has inrush current and is rated separately in horsepower. Incandescent lamps have a lower tungsten rating still. Always compare your appliance’s label to the timer’s stated ratings for the same load type.
At a glance
| Model | Type | Stated ratings and features | Limits |
|---|---|---|---|
| Intermatic HB113 | Plug-in mechanical | 20 A resistive at 125 VAC; 12 A for air conditioners; 5-20 plug configuration; motor load 1 HP at 125 VAC; 24-hour schedule; 2 ON and 2 OFF settings per day with removable trippers; minimum 30-minute ON or OFF time | Needs a matching 20-amp outlet for its plug; indoor use only; one appliance only |
| Intermatic KM2ST-1G | In-wall mechanical | For circuits up to 20 A | Hardwired, replaces a wall switch |
| Intermatic EI600 series (for example EI600WC) | In-wall electronic | 7-day programmable schedules; 120 to 277 VAC; 20 A; the EI600WC lists 1875 W | Hardwired; check the load type and wattage on the specific model |
| Legrand Pass and Seymour PLT26351BK | In-wall plug-load timer receptacle | 20 A, 125 V heavy-duty spec grade; two individual programs; indoor only | Hardwired; no weather-resistant rating |
| Intermatic P1101 | Outdoor plug-in mechanical | Outdoor mechanical plug-in timer with a built-in enclosure, per the maker’s catalog | Rating not confirmed for this guide; read the maker’s page for your load |
The options in detail
Intermatic HB113 plug-in timer
The HB113 is described by Intermatic as a heavy-duty appliance timer for window air conditioners and other heavy-duty appliances with specialized NEMA plugs. Its ratings are 20 amps resistive at 125 volts with a 5-20 plug and a one-horsepower motor rating at 125 volts, and retailer listings add a 12-amp air-conditioner rating, so check your unit’s label against that lower figure. It is for indoor use only. It plugs directly into a wall outlet, and the schedule is a 24-hour mechanical dial with two on and two off settings per day, set with removable trippers, with a minimum of 30 minutes on or off. It is a good fit for pumps, large fans and window air conditioners, subject to the appliance’s own rating. A mechanical dial is simple and does not need batteries or programming, but it repeats the same schedule every day.
Intermatic lists related heavy-duty appliance timers in the same family, such as the HB112 and HB114, but their specifications were not confirmed for this guide, so read their product pages before choosing.
Intermatic in-wall timers
The KM2ST-1G is a mechanical in-wall timer for circuits up to 20 amps, and the EI600 series are electronic timers with seven-day programmable schedules, a 120 to 277 volt range and a 20-amp rating. The EI600WC lists 1875 watts. These replace a wall switch and control whatever the switch controls: lights, a ventilation fan or a hardwired load. They are not plug-in devices, so wiring and load selection belong to an electrician or competent installer following the manual and local code. Neutral requirements differ by model, so read the manual.
Legrand Pass and Seymour PLT26351BK
This is a hardwired, in-wall heavy-duty timer receptacle, rated 20 amps at 125 volts, with two individual programs. Legrand lists it as indoor only with no weather-resistant rating. It is useful where you want a timed outlet in a fixed place, such as a workshop or a storage room, and where the receptacle itself should be timed. It is not a plug-in device.
Outdoor options
Intermatic’s catalog describes grounded plug-in timers with a flip-open enclosure rated for outdoor use, suitable for pumps, landscape lighting or holiday lighting, and lists the P1101 as an outdoor mechanical plug-in timer with a built-in enclosure. Read the model’s stated rating before connecting a 20-amp load; many outdoor timers are 15 amps.
Matching the timer to the load
- Resistive: Heaters, heat tape and similar loads. The HB113’s resistive rating is 20 amps at 125 volts.
- Motor: Pumps, compressors and air conditioners have startup surges. The HB113 lists a one-horsepower motor rating. Check your appliance’s rating plate.
- Tungsten: Incandescent lighting has a much lower limit than resistive heating; look for the tungsten figure on the timer’s label.
- LED and electronic loads: Some timers have minimum or special load ratings for LEDs and electronics. Read the maker’s rating.
- Plug configuration: The HB113 has a 5-20 plug, which needs a matching 20-amp receptacle. A standard 15-amp receptacle does not accept it. Do not modify plugs or receptacles to force a fit.
Budget, mid-range and premium tiers
Mechanical dial timers sit at the budget end: simple and effective for a daily on-off cycle. Electronic programmable timers sit in the middle, adding weekly schedules and often astronomical or holiday features. Premium options are heavy-duty commercial timers such as the spec-grade PLT26351BK or Wi-Fi in-wall controls, built for repeated use on 20-amp circuits. Hardwired timers also add installation labor to the project.
Installation and safety notes
For a plug-in timer, plug it directly into a wall outlet, not into a power strip or extension cord, and keep the load within the timer’s rating. Follow the manual. For a hardwired timer, switch off the circuit at the breaker and follow the manual and local code, or hire a licensed electrician. Do not defeat grounding or use adapters to fit a plug into a mismatched outlet. Do not put a timer on a heating appliance unless the appliance’s manual allows being switched on automatically, because a heater that starts unattended is a risk. Do not use a timer to control medical equipment. If a timer or outlet becomes hot or discolored, stop using it.
Setting a mechanical timer
On a dial timer such as the HB113, you rotate the dial to the current time of day, then slide the removable trippers to the hours you want the load on or off. Because the minimum on or off period is 30 minutes, plan schedules in half-hour blocks. If the appliance has its own thermostat or control panel, leave it in the mode that lets it restart by itself after power returns, and read its manual to see whether that is allowed.
Pick X if …
| If you want… | Pick | Why |
|---|---|---|
| A plug-in timer for a window air conditioner or pump | Intermatic HB113 | 20 A resistive and 1 HP motor rating, 5-20 plug; 12 A listed for air conditioners |
| A timed receptacle in a fixed indoor location | Legrand PLT26351BK | 20 A, 125 V spec grade, two programs |
| A 7-day programmable in-wall timer | Intermatic EI600 series | 7-day schedule, 120 to 277 VAC, 20 A |
| A simple mechanical in-wall timer | Intermatic KM2ST-1G | Circuits up to 20 A |
| An outdoor plug-in timer | Intermatic P1101 or similar | Built-in enclosure; confirm the amp rating |
Alternatives
- Smart plugs rated for 15 amps: These offer app scheduling but usually do not handle a full 20-amp load; read their ratings.
- Appliance with a built-in timer: Many window air conditioners and pumps already have timers or smart controls.
- Time-delay or cycle timers: For ventilation or lighting, a countdown switch may suit better than a daily schedule.
Frequently Asked Questions
Can a 15-amp timer be used on a 20-amp circuit?
The timer must be rated for the load it controls, not just the circuit. A 15-amp timer on a 20-amp circuit is acceptable only if the connected appliance stays within 15 amps. For heavy appliances, choose a 20-amp-rated timer.
Will the HB113 fit a regular outlet?
The maker lists a 5-20 plug configuration, which is for a 20-amp receptacle with a T-shaped slot. A standard 15-amp receptacle does not accept it. Do not modify plugs or outlets.
Can I time an air conditioner?
The HB113 is marketed for window air conditioners, with a one-horsepower motor rating at 125 volts. Compare your unit’s rating plate with those figures, including the 12-amp air-conditioner rating retailers list, and read the air conditioner’s manual about being powered on automatically.
Is an in-wall timer better than a plug-in timer?
An in-wall timer is a permanent solution that replaces a switch or receptacle and needs wiring. A plug-in timer needs no wiring and moves with you. Choose by whether the installation is permanent.
Can I use a timer outdoors?
Only a timer rated for outdoor use, with an enclosure, as the maker states. The HB113 and PLT26351BK are listed indoor only. Follow the manual and local code for outdoor outlets.
Why does a timer click but my device does not turn on?
Check that the load is within the timer’s rating, the schedule trippers are set correctly and the timer is on the correct mode. If the device still does not run, stop and consult the manual or an electrician.
Further reading