Key takeaways
- Add up the watts: Look at the heater’s label. A 1000-watt heater at 120 volts draws about 8.3 amps, which is within a 10-amp controller but close to the limit.
- Resistive loads are easiest: Plain resistive heaters, heat mats and heat lamps are the simplest loads. Motor and compressor loads such as refrigerators have inrush current, so use the compressor delay and check the maker’s guidance.
- Do not exceed the rating: If the heater draws more than the controller’s rating, use a controller with a higher rating or a relay approved for the load, installed by someone qualified.
- Cooling loads: A freezer or refrigerator needs compressor delay, which the ITC-308 provides.
A temperature controlled on/off switch is a thermostat controller with a plug-in outlet and a probe that switches a connected heater, fan or cooler according to a set temperature, and the best-documented family is Inkbird’s ITC-308 line: the ITC-308 for a wired, dual-output controller, the ITC-308-WIFI for app control and the ITC-308S, which reviewers describe as the same controller with a plug-in replaceable probe. It suits seed starting, fermentation, reptile or aquarium heating, small greenhouses and similar jobs where you want a plain heater or cooler to hold a target temperature. It is not a substitute for the safety devices built into heaters, and its load limits must be respected.
What this device does
You plug the controller into a wall outlet, plug a heater and/or a cooler into its sockets, and place the probe where you want to measure temperature. The controller compares the probe reading to your setpoint and switches the sockets on or off. Dual-output controllers have one socket for heating and another for cooling, so one unit can hold a temperature by switching either side. This is different from a smart plug with a timer, which switches on a schedule rather than in response to a measured temperature, and from a hardwired line-voltage thermostat, which is installed in a wall or an enclosure.
At a glance
| Model | Stated features | Stated range and accuracy | Load notes |
|---|---|---|---|
| Inkbird ITC-308 | Dual-stage, dual relay output so heating and cooling are controlled independently; compressor delay; temperature calibration; high and low alarms; sensor-fault notification | -50 to 120 C (-58 to 248 F); accuracy plus or minus 1 C (2 F); resolution 0.1 below 100 degrees, 1 degree at 100 and above | Listings differ: 1100 W at 110 V on many retailer pages, 1200 W on the maker’s own page; 10 A |
| Inkbird ITC-308-WIFI | Same dual outputs plus the free Inkbird app (iOS 11.0 or later, Android 5.0 or later) | -40 to 100 C (-40 to 212 F) | Pages list 1100 W or 1200 W at 110 V; higher at 220 V; 10 A |
| Inkbird ITC-308S | Same dual-stage controller as the ITC-308 per reviewers, with a plug-in replaceable probe; no Wi-Fi version | Reviewers report the same specifications as the ITC-308 | Sources list 1100 or 1200 W at 110 V; 10 A |
| Inkbird ITC-306A | Wi-Fi aquarium heater controller with two probes; heating only | Control range differs by listing and version; the maker lists a wide range, some retailers 20 to 35 C | 10 A, 1200 W at 120 V per listings |
Inkbird’s support material has said the ITC-308 at 110 volts supports devices up to 10 A and 1100 W, and that the heater’s and cooler’s power must match the controller’s output, while its current product page lists 1200 W. Treat 1100 watts as the safe working limit when two listings differ.
The Inkbird options in detail
ITC-308
This is the base model. It uses an NTC sensor attached to the unit, with a cable length of about 1.8 metres (6 feet) listed on one regional spec sheet. The dual relay output means you can use a heater and a cooler at the same time with independent control. A compressor delay function holds off restarting a refrigerator or freezer compressor after it shuts down, which protects the compressor from short cycling. Temperature calibration lets you correct for a probe offset, and high and low alarms warn you if the temperature drifts out of range. The listed temperature range is wide enough for everything from fridge conversions to warm propagation setups.
ITC-308-WIFI
The Wi-Fi model adds app monitoring and control through Inkbird’s free app on iOS and Android. Its listed range is narrower, from -40 to 100 degrees Celsius, and its supply is listed as 100 to 230 volts, with a higher maximum wattage at 220 volts. This matters if you want notifications when a fermenter goes out of range while you are away. It also depends on your home network, and a controller that is offline still holds its settings, but check the maker’s documentation for how it behaves during a network outage.
ITC-308S
Reviewers describe the ITC-308S as the same dual-stage controller as the ITC-308, with a plug-in, replaceable probe, and the maker does not list a Wi-Fi version of it. If you worry about probe wear in a damp environment, a replaceable probe makes servicing simpler. Check the rating on the unit you buy.
ITC-306A
The ITC-306A is Inkbird’s Wi-Fi aquarium heater controller, sold with two probes. Listings describe an abnormal-protection relay and an alarm if the two probes disagree by a few degrees, and the outlets are for heaters rather than coolers. Aquarium heaters typically have their own thermostats too, so treat it as a second layer, not a replacement. Listings give 10 amps and 1200 watts at 120 volts.
Choosing by load
- Add up the watts: Look at the heater’s label. A 1000-watt heater at 120 volts draws about 8.3 amps, which is within a 10-amp controller but close to the limit.
- Resistive loads are easiest: Plain resistive heaters, heat mats and heat lamps are the simplest loads. Motor and compressor loads such as refrigerators have inrush current, so use the compressor delay and check the maker’s guidance.
- Do not exceed the rating: If the heater draws more than the controller’s rating, use a controller with a higher rating or a relay approved for the load, installed by someone qualified.
- Cooling loads: A freezer or refrigerator needs compressor delay, which the ITC-308 provides.
Safety and placement notes
A temperature controller is a convenience device, not a safety device. It does not replace a heater’s own over-temperature protection, and the maker does not claim it prevents fires or injuries. Keep it and the heater clear of flammable materials, follow the heater’s manual, and do not cover the controller. Keep the controller and its plug out of splash zones, since many are not rated for wet locations; if you use it near an aquarium, create a drip loop in the cord and keep it above the water level. Use only equipment listed for your region, plug the controller into a properly grounded outlet, and do not use damaged cords. If a controller or plug becomes hot, stop using it.
Place the probe in the air or water you want to measure, not touching the heater. In a fermentation fridge, taping the probe to the side of a carboy under insulation measures the liquid more closely than air does. Test the setup with a separate thermometer before trusting it with a valuable batch or animals.
Budget, mid-range and premium tiers
The budget tier is a basic single-output plug-in thermostat. Mid-range, where the ITC-308 sits, adds dual outputs, a delay for compressors, calibration and alarms. Premium units add Wi-Fi and app features like the ITC-308-WIFI, remote monitoring and notifications. Choose by what you must control: a heat mat needs only heating, a kegerator needs a cooler with compressor delay, and a homebrew fridge-and-heater setup benefits from dual outputs.
Setting it up sensibly
Set the target temperature and the differential, which is the gap between switching on and switching off, so the heater does not cycle too rapidly. Use the calibration function after comparing the display with a reference thermometer. Set the high and low alarms a few degrees beyond the range you can tolerate so a stuck heater or a failed probe shows up early, and read the manual’s section on what the controller does if the probe is disconnected.
Pick X if …
| If you want… | Pick | Why |
|---|---|---|
| Heating and cooling from one controller | Inkbird ITC-308 | Dual relay outputs, controlled independently |
| Remote monitoring and alerts | Inkbird ITC-308-WIFI | App control on iOS and Android |
| A replaceable probe | Inkbird ITC-308S | Plug-in replaceable probe |
| Aquarium heater control | Inkbird ITC-306A | Wi-Fi aquarium heater model with two probes |
| A refrigerator or freezer conversion | ITC-308 family | Compressor delay function |
| A heater above about 1100 W | A controller or relay rated higher | Controller limit is about 1100 to 1200 W at 110 V, 10 A |
Alternatives
- Hardwired line-voltage thermostats: They are installed in an enclosure or wall and have higher ratings, but wiring should be done by a licensed electrician following the manual and local code.
- Heater with built-in thermostat: Many heaters, such as aquarium and room heaters, already include one. A separate controller adds a second layer of control but should not replace the first.
- Smart plug with a temperature sensor and scene logic: Some smart-home systems can switch plugs by temperature; check the plug’s load rating and whether it is suited to heaters.
Frequently Asked Questions
What is a temperature controlled on/off switch?
It is a controller with a temperature probe and a power outlet. It turns a plugged-in device on or off to hold a target temperature. Dual-output versions can control a heater and a cooler.
How much power can the Inkbird ITC-308 handle?
Inkbird lists about 1100 watts at 110 volts, and some pages list 1200 watts at 120 volts, with a 10-amp limit. When listings differ, stay at or below 1100 watts and match the heater to the controller.
Can I use it with a refrigerator?
Yes, a compressor delay function is built into the ITC-308, which helps avoid restarting the compressor too quickly. Check the appliance’s current rating and the maker’s guidance.
Does the Wi-Fi model work without the internet?
The maker’s documentation describes the app features. A controller generally keeps its settings if the network drops, but read the manual for specifics on offline behavior.
Is it safe to leave a heater on a controller unattended?
The controller does not replace the heater’s own safety features, and no device can guarantee safety. Use heaters designed for continuous operation, follow their manuals, and test the setup with an independent thermometer.
Where should the probe go?
Place it where you want to measure the temperature, away from direct contact with the heater. For liquids, secure it against the container; for air, place it at the height of the plants or animals.
Further reading