Key takeaways
- Floor construction: Concrete slab, concrete over metal deck, raised floor or wood framing each need different products.
- Fire rating: Match the device to the floor’s required rating and install it per the maker.
- Prewired or unwired: Prewired units save time; unwired units let you defer choices on receptacles and data.
- Cover type: Flush for tile, surface for carpet, and consider lid style for foot traffic.
- Moisture: The 4-inch Evolution model is described as scrub-water rated when installed per the instructions. Do not assume that rating means it is waterproof or suitable for flooding.
- Tamper-resistant outlets and ground-fault protection: Code usually requires these in some locations; a licensed electrician applies the local rules.
- Data and USB: Some configurations carry network or other low-voltage connections, and these must be separated from power as code requires.
In-floor plug sockets are recessed power outlets set into a floor, and the best-documented current line is Legrand’s Wiremold Evolution series of recessed poke-thru devices, which come prewired or unwired, in 4-, 6-, 8- and 10-inch sizes, with flush covers for tile and surface covers for carpet. They are mainly commercial and installer-specified products for open offices, conference rooms and meeting spaces, so a home buyer would rarely buy one retail and install it alone. If you want one for a home, a licensed electrician must assess your floor construction, fire-rating rules and local code before any hole is cut.
What in-floor sockets are, and where they fit
An in-floor socket, also called a floor box or poke-thru device, brings power and sometimes data up through a floor slab to a spot in the middle of a room, such as under a sofa, a kitchen island or a conference table. The terms matter. A floor box is cast or fitted into the concrete before or during the pour. A poke-thru device is installed from above in a hole drilled through a finished floor slab, with wiring routed from the ceiling below. A furniture-feed unit does not offer outlets at the floor surface; it feeds power to furniture. In some countries, “plug sockets” is the everyday term for outlets, and requirements for floor outlets differ widely by country and region.
Floors are fire-rated assemblies in many buildings. Any device that penetrates them must keep the fire rating, and wiring must meet local code. That is why in-floor products are specified by electrical designers and installed by licensed professionals. For wood-framed or slab floors in a house, the options and rules differ again, so ask a qualified electrician.
At a glance
| Product | Type | Stated features | Limits |
|---|---|---|---|
| Wiremold Evolution 6AT prewired | Recessed poke-thru, prewired | Comes fully assembled with every power receptacle already installed; flush or surface cover styles; cover opens a full 180 degrees | Installation requirements for slab depth apply; professional installation |
| Wiremold Evolution 8AT unwired | Recessed poke-thru, unwired | Lets you connect to conduits and install now, then choose configuration and plates later; flush style cover for tile | Needs electrical and data completion by a professional |
| Wiremold Evolution 4AT unwired | Recessed poke-thru | 4-inch size; the maker describes the 4-inch model as scrub-water rated when installed per the instructions | Smaller capacity |
| Evolution 3-hour stem assemblies (for example 6STCP3H) | Recessed poke-thru, 3-hour fire rating version | Legrand lists separate 3-hour assemblies for floors that need them; the standard devices are listed for up to 2 hours | Select for floor assemblies that require it |
The Evolution series in more detail
Sizes and capacity
Legrand’s Evolution poke-thru devices come in 4-, 6-, 8- and 10-inch configurations, with larger sizes holding more receptacles and data connections. Larger sizes hold more receptacles and data connections. The devices sit recessed below floor level, which Legrand says provides protection and longevity, and the cover opens a full 180 degrees with sliding doors. That design keeps the cover flat while in use and lets a cord pass through.
Fire-rating
Legrand states that intumescent material maintains the floor’s fire rating for up to two hours on the standard devices, and it lists separate three-hour stem assemblies. Some product pages are inconsistent about the three-hour figure, so confirm the part number against the maker’s listing. The fire rating applies to the installed assembly, so the right product depends on the floor rating where it is installed. Do not assume any device keeps a rating by itself.
Cover styles and floors
Flush covers are intended for tile and similar hard floor covering, so the device sits level with the top of the floor covering, while surface covers suit carpet. Flush styles are easier to walk over but need careful installation relative to the finished floor height.
Floor depth and structure
Legrand’s data sheets describe installation into reinforced concrete floors, and the minimum slab depth for each device is in its installation sheet and the fire-resistance listing, so read those before planning. A wood-framed floor, thin topping or post-tensioned slab may not suit these devices. Post-tensioned slabs in particular must not be drilled without a professional scan. A structural engineer and electrician can confirm what your floor allows.
Discontinued items
Legrand’s older recessed floor boxes, including the RFB2E two-compartment box seen in the maker’s catalog, are marked discontinued, so avoid choosing them for a new project even if a retailer lists stock.
What to look for
- Floor construction: Concrete slab, concrete over metal deck, raised floor or wood framing each need different products.
- Fire rating: Match the device to the floor’s required rating and install it per the maker.
- Prewired or unwired: Prewired units save time; unwired units let you defer choices on receptacles and data.
- Cover type: Flush for tile, surface for carpet, and consider lid style for foot traffic.
- Moisture: The 4-inch Evolution model is described as scrub-water rated when installed per the instructions. Do not assume that rating means it is waterproof or suitable for flooding.
- Tamper-resistant outlets and ground-fault protection: Code usually requires these in some locations; a licensed electrician applies the local rules.
- Data and USB: Some configurations carry network or other low-voltage connections, and these must be separated from power as code requires.
Installation, safety and code notes
Do not cut or core a floor slab without knowing what is inside. Concrete slabs may contain reinforcing steel, post-tension cables, conduit or radiant heating, and cutting them can cause serious damage or injury. A qualified contractor should scan the slab first. Wiring to the device should be installed by a licensed electrician following the manual and local code. Floor outlets must be rated for their location; in kitchens and bathrooms, rules on where outlets may go differ. Do not use an extension cord from a floor outlet across a walkway as a permanent arrangement, and never bypass ground-fault or tamper-resistant protection.
Budget, mid-range and premium tiers
Because these are installed products, budget thinking should include labor. A budget approach is a surface-mounted raceway or a cord cover, which avoids penetrating the floor. Mid-range is a standard unwired poke-thru that you finish later. Premium is a prewired, high-capacity unit with a fire-rated assembly and flush finishing for visible spaces. Floors with fire rating, tile and data requirements push costs up, mostly due to labor.
Planning questions to settle first
Before choosing a product, decide how many outlets and data connections the spot needs, what the floor finish will be, who will use the area and whether cords will cross a walkway. Ask the electrician to confirm the slab depth, the fire rating, the route for conduit from above or below, and whether the building owner or local authority must approve penetrations. Settling these first usually decides which Evolution size and cover style makes sense.
Pick X if …
| If you want… | Pick | Why |
|---|---|---|
| A ready-to-connect unit with receptacles installed | Evolution 6AT prewired | Fully assembled, receptacles already installed |
| To install conduit now and choose outlets later | Evolution 8AT unwired | Install now, configure later |
| A compact unit | Evolution 4AT | 4-inch model |
| A 3-hour fire-rated floor assembly | The Evolution 3H stem assemblies | Three-hour assemblies listed separately by Legrand |
| Power to furniture, not outlets in the floor | A furniture-feed device from the same maker | Check the model page for the intended use |
| A tile floor with no raised lid | Flush-style Evolution cover | Sits level with the floor covering |
Alternatives
- Table or furniture power: Wiremold and other makers sell cord-fed pop-up towers and table power units. They need no floor penetration; check each model’s stated ratings.
- Surface raceway or floor cord cover: A low-profile raceway brings power from a wall without cutting the floor.
- Relocating the furniture or adding a wall outlet: Often simpler and cheaper than trenching or drilling a floor.
Frequently Asked Questions
Are in-floor outlets safe?
Products from established makers are designed and listed for floor use when installed to the instructions, but safety also depends on correct installation, location and use. Have a licensed electrician install them and follow local code.
Can I add an in-floor outlet to a concrete slab at home?
It may be possible, but the slab must be scanned for steel, conduit and post-tension cables first. Legrand’s installation sheets state minimum slab requirements, and local code and fire rules may apply. Consult a licensed contractor.
What is the difference between a floor box and a poke-thru?
A floor box is typically cast into the slab or installed during construction, while a poke-thru is installed from above through a hole drilled in the finished slab and wired from below. The right choice depends on the floor and the project stage.
Are in-floor outlets waterproof?
Not by default. Legrand describes its 4-inch Evolution model as scrub-water rated when installed per the instructions, which is not the same as waterproof. Follow the manual and local code for wet areas.
Do in-floor outlets reduce the floor’s fire rating?
Fire-rated poke-thru devices use intumescent material to maintain the floor’s rating, per Legrand, with two-hour ratings on the standard devices and separate three-hour assemblies. The assembly must be installed as specified, and a professional should confirm the rating needed.
What if I only want power for a sofa or desk?
A furniture-feed device or a cord-fed power tower may be more suitable than a full floor outlet, and neither requires cutting the slab in the same way.
Further reading